Please use this identifier to cite or link to this item:
https://elib.utmn.ru/jspui/handle/ru-tsu/39092| Title: | Improving the efficiency of the heat stabilizer operation by distributing refrigerant flows inside the device and finning its surfaces Повышение эффективности работы термостабилизатора за счёт распределения потоков хладагента внутри устройства и оребрения его поверхностей |
| Authors: | Gilmanov, A. Ya. Kim, A. S. Shevelev, A. P. Гильманов, А. Я. Ким, А. С. Шевелев, А. П. |
| Keywords: | cryolithozone finning heat and mass transfer heat stabilizer main pipelines physical and mathematical modeling refrigerant vertical temperature profile |
| Issue Date: | 2025 |
| Publisher: | Tomsk Polytechnic University, Publishing House |
| Citation: | Gilmanov, A. Y., Kim, A. S., Shevelev, A. P. (2025). Improving the efficiency of the heat stabilizer operation by distributing refrigerant flows inside the device and finning its surfaces. Izvestiya Tomskogo Politekhnicheskogo Universiteta Inziniring Georesursov, 336(4), 25–35. doi:10.18799/24131830/2025/4/4639 |
| Abstract: | Relevance. The construction of long pipelines in the conditions of the cryolithozone is associated with the problem of soil thawing under them. An effective solution to this problem is the use of two-phase heat stabilizers located next to the piles. To increase the efficiency of the device, it is proposed to fin the inner surface of the aboveground part of the thermosyphon. Aim. To determine the optimal parameters of the finning of the thermosyphon surfaces and the number of segments of the device separating the refrigerant flows. Objects. Heat stabilizer, refrigerant, heat and mass transfer, frozen soil. Methods. The developed model uses the laws of non-isothermal multiphase mechanics. There are five related subtasks: blowing of the above-ground part of the heat stabilizer; condensation of the refrigerant inside the above-ground part of the device; movement of the refrigerant inside the flow-separating device; upward flow of the refrigerant; heat exchange of the heat stabilizer with frozen soil. Results and conclusions. The validation of the proposed model was carried out by comparing the calculated data with measurements of the temperature profile for the Salekhard State Archive building. The work shows that increasing the size of the fins of the outer surface of the underground part of the heat stabilizer and segmenting the device separating the refrigerant flows makes it possible to evenly cool the soil in an area not subject to seasonal thawing. It was found that increasing the contact area of the refrigerant with the inner surface of the aboveground part of the thermosyphon due to the finning of this surface makes it possible to increase the average value of the ambient temperature limit at which the device is effective. © 2025 Tomsk Polytechnic University, Publishing House. All rights reserved. |
| URI: | https://elib.utmn.ru/jspui/handle/ru-tsu/39092 |
| ISSN: | 2500-1019 |
| Appears in Collections: | Научные публикации, проиндексированные в SCOPUS и WoS |
Files in This Item:
| File | Description | Size | Format | |
|---|---|---|---|---|
| 2-s2.0-105004029331.pdf | 1,24 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.